Model LT-15 Digital Leakage Current Tester


  • Features product ground switching (grounding conductor maintained to device under test when not measuring leakage).
  • Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation).
  • These are the only leakage current testers designed and supported by product safety experts.
  • These testers come fully setup, ready to use, and are calibrated by our unique in the world ACLAS accredited Calibration Lab.
  • Full technical support available by experienced safety engineers.
  • Laboratory, Production Line, and Field Testing in accordance with UL, IEC, CSA, EN and CE requirements



Testing Tolerance 90 -132 / 180 – 264 VAC Display 3.5 in digital LCD display
Measurement Ranges 2 mA/Resolution: 1.0 μA, Accuracy: ±1% full scale
20 mA/Resolution: 10.0 μA, Accuracy: ±1% full scaleDimensions Weight 
13.25 in. W x 11.5 in. D x 5.5 in. H
9 lbs.
Input / Output Ratings 100 -120 / 200-240 VAC 15 A 50-60 Hz Body Impedance Circuits 1500 Ω, 1% resistance shunted by 0.15 μF, 1% capacitance, compliant with standards requiring that body circuit
Leakage current Measurement Switch Can be measured through:

  • product power cord ground conductor; Surface-to-Line 1/Line OR Ground; Surface-to-Surface

Model LT-30HC Digital Leakage Current Tester


  • Features product ground switching (grounding conductor maintained to device under test when not measuring leakage).
  • Automatic front receptacle disconnects when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation).
  • These are the only leakage current testers designed and supported by product safety experts.
  • Full technical support available by experienced safety engineers.



Display 3.5 in. digital LCD display Dimension Weight 13.25 in. W x 11.5 in. D x 5.5 in. H
13 lbs.
Input/output Ratings 100 -120 / 200-240 VAC 30 A 50-60 Hz Measurement Ranges 2 mA/Resolution: 1.0 μA, Accuracy: ± 1% full scale
20 mA/Resolution: 10.0 μA, Accuracy: ± 1% full scale
Leakage Current Measurement Switch Can be measured through:

  • product power cord ground conductor; Surface-to-Line 1/Line 2 OR Ground; Surface-to-Surface
Body Impedance Circuits 1500 Ω, 1% resistance shunted by 0.15 μF, 1% capacitance, compliant with standards requiring that body circuit
Testing Tolerance 90 -132 / 180 – 264 VAC

Model LT-601 and LT-601HC Digital Leakage Current Tester


  • The LT-601 and LT-601HC meets UL, CSA, CE, EN, IEC, MI standards… These devices also meet standards for Medical product safety testing!
  • Through product’s power cord ground conductor
  • Surface/Patient-to-Ground
  • Patient-to-Patient



Display 3.5 in. digital LCD display Mechanical Size: 13.25 in. W x 11.5 in. D x 5.5 in. H
LT-601: Weight: 9 lbs.
LT-601HC Weight: 13 lbs.
Input Ratings LT-601: 100-120/200-240 VAC 15 A 50-60 Hz

LT-601HC: 100-120/200-240 VAC 30 A 50-60 Hz

Testing tolerance: 90-132 / 180-264 VAC

Measurement Ranges 200 μA/Resolution: 1.0 μA, Accuracy: ± 1% full scale
2000 μA/Resolution: 10.0 μA, Accuracy: ± 1% full scale
Output Ratings Same as input ratings Body Impedance Circuits Network in accordance with IEC 60601, EN 60601, CSA 601, UL 2601

Model LT–952 and LT–952HC Digital Leakage Current Tester


  • Universal rear panel receptacle allows for testing products with any plug configuration
  • True RMS meter measures sinusoidal and non-sinusoidal wave shapes… (Important when testing products using switch mode power supply which can generate non-sinusoidal leakage currents).
  • Calibrated, traceable to NIST
  • Lightweight, with integral handle.
  • Meets UL, CSA, CE, EN, IEC and all other international safety agency requirements.
  • Test can be performed in seconds! Pays for itself in time and stress savings.



Input Ratings LT-952: 100-120/200-240VAC 15 A 50-60 Hz
LT-952HC: 100-120/200-240 VAC 30 A 50-60 Hz
Testing tolerance: 90-132 / 180-264 VAC
Mechanical Size: 13.25 in. W x 11.5 in. D x 5.5 in. H
LT-952: Weight: 9 lbs.
LT-952HC Weight: 13 lbs.
Output Ratings Same as inputratings Measurement Ranges 2 mA/Resolution:1.0 μA, Accuracy: ± 1% full scale
20 mA/Resolution: 10.0 μA, Accuracy: ± 1% fullscale
Display 3.5 in. digitalLCD display Body Impedance Circuits Body Circuitper IEC 60950 2nd edition,
IEC 61010, IEC 60335, IEC 60065
, and others based on IEC 60 standards

Model AVO–LT1 Applied Voltage option


  • Custom designed low capacitance transformer provides high isolation
  • Safety features include line isolation, a voltage applied warning lamp, safety banana jacks, and an output current limiter
  • Input and output voltage ranges from 90-264 VAC without having to change a range switch
  • A separate set of output jacks is provided for connecting an external output monitoring meter



Input Ratings 100 – 240 VAC less than 0.1 A 50/60 Hz Current 5 mA max. @ 240 VAC
Impedance 47 Kohm Weight 2 lbs. (1 Kg)
Size 6-1/8″ W x 3-1/4″ H x 6-1/4″ D Output Voltage 1:1 isolation of input voltage
Isolation Method Low leakage custom designed transformer

 

LT Low Current Power Cord


  • 15 Amp power cord for Leakage Current Testers

LT High Current Power Cord



  • 30 Amp Cord for Leakage Current Testers


LT Test Lead Kit


  • Leads provide a connection to the banana jacks installed in the front of the unit and used to measure the leakage between any two surfaces on the product under test.

LT Accessory Plug



  • 30 Amp Cord for Leakage Current Testers