GLT 400 midi Logger

GLT 400 midi Logger

GLT 400 is a multipurpose data logger for:

  • Standalone or PC hosted data logger for R&D, Quality and Production.
  • Ideal for Factory Automation with ModBus/TCP interface

It is used for measuring, recording signals such as Temperature, Humidity, Acceleration, Carbon Dioxide, Illuminance (UV), Voltage and Current, logic, and pulse signals.

Features:
  • 20 Analog Input Channels
  • Expandable to 200 channels
    1. Selectable input terminals – screw type, screwless and high accuracy and high isolation
  • Voltage range: ±20 mV to ±100 V over 12 ranges
  • Sampling rate: 10 ms to 1 hour
  • 4 discrete input channels
  • 4 discrete alarm outputs
  • Internal storage 4GB, removable external storage up to 32GB
  • Recorded data can be transferred to PLC as additional i/o
  • Power source: (2) AA Batteries, AC, DC
  • Communication Interface: USB or LAN/ Ethernet
  • Ambient conditions of operation: -20~60℃ (with selective power source)
  • Software: Windows based
Download the Brochure

Accessories List

Image
ACADP-20 AC ADAPTER with AC power cable (CE) for GL series

AC adapter that is supplied as a standard accessory.
Input supply: 100 to 240 VAC, 50/60 Hz

Image
B-513 Logic/Alarm Cable

The Input/output cable for GL data logger enables 4 channels of
logic/pulse input, external trigger input, and alarm signal output.

Image
B-530 Humidity sensor (3m)
  • Allowable temperature range: -25 to +80°C
  • Allowable humidity range: 0 to 100% RH
  • Relative humidity measurement accuracy: ±3% RH (5 to 98% RH at 25°C)
  • Method: Capacitance method
  • Response time: 15 sec. (90% response when membrane filter is installed)
  • Cable length 3 m
  • Sensor power source: DC +5 to +16 V
  • Power consumption approx. 4 mA

Image
B-569 Battery pack
    • Capacity: 7.2V/2900mAh
    • Battery type: Lithium secondary battery

    When LCD is ON

      • Battery pack x 1 (brightness MAX): approx. 3 hours
      • Battery pack x 2 (brightness MIN): approx. 6 hours

    When LCD is OFF

    • Battery pack x 1: approx. 5 hours
    • Battery pack x 2: approx. 10 hours
    • Charging method Mount in the main unit
      • Time required for charging
        • Battery pack x 1: approx. 5 hours
        • Battery pack x 2: approx. 10 hours
      • The power supply will be switched automatically to the battery in the event of a power failure.
      • The AC adapter is the primary power source.
      • Operation environment Running on battery: 0 to 40°C,
      • Battery being charged: 15 to 35°C

Image
B-514 DC power cable (2m)

GL 240 can be powered on using DC power: 8.5 to 26.4 VDC range.
DC drive cable is an optional item and is used when operating a logger with DC power.